ReserveHome backup power, engineered

Tier 1 guide

Indoor medical backup power with LiFePO4 stations

Battery power stations listed for indoor use can run CPAPs, concentrators and routers without combustion. Size them on duty cycle and conversion losses, prefer DC where the device maker allows, and treat UPS mode as helpful, not guaranteed.

Data labels: Manufacturer stated Calculated Planning estimate Pending verification

How much battery do my medical devices actually need?

Most sizing calculators look only at running wattage. Accurate runtime needs duty cycle and conversion efficiency, so we split equipment into resistive heating loads, steady compressor loads and intermittent motor cycles.

Runtime (hours) = Battery Wh × 0.90 usable depth of discharge × conversion efficiency (0.85 for AC inverter output, 0.95 for DC ports) ÷ continuous load (W).

CPAP and BiPAP machines (ResMed AirSense 10/11, Philips DreamStation)

  • The humidifier multiplier. At around 10 cmH2O with the heated humidifier and tube off, a typical CPAP draws roughly 15–25 W (120–200 Wh per 8-hour night). With heat on, consumption commonly rises to 60–90 W (480–720 Wh per night). Planning estimate
  • The DC-to-DC advantage. Through the AC plug, the station inverts DC to 120 V AC and the CPAP brick converts it back to DC. Using the CPAP maker's approved 12 V/24 V DC cord avoids that loss. Reserve models AC at 0.85 and DC at 0.95 efficiency, which is roughly a 12% runtime gain from the cord alone, more when it also lets the AC inverter switch off.

Oxygen concentrators: home vs portable

  • Continuous-flow home units (e.g., Inogen At Home, Philips EverFlo) commonly draw 280–350 W. At 300 W on AC, a 2,048 Wh station runs about 5.22 hours. Calculated
  • Pulse-dose portables such as the Inogen One G5 draw roughly 18–45 W depending on setting. At 25 W on DC, a 2,048 Wh station runs about 70.04 hours. Calculated

Motorized lift chairs and hospital beds

Actuators pull roughly 150–250 W while moving and essentially nothing at rest. Use is brief, so energy is small, but follow the maker's power requirements; pure sine output is the safe default for actuator controls.

How long will a 2 kWh or 4 kWh station run each device?

Medical and essential indoor equipment runtime matrix (calculated with Reserve formula)
DeviceOperating profileAvg continuous drawStarting surgeOutput typeRuntime on 2,048 Wh (e.g., BLUETTI AC200L)Runtime on 4,096 Wh (e.g., EcoFlow DELTA Pro 3)
CPAP, no heat, DC cordContinuous 8 h20 WNone12/24 V DC87.55 h (~10.9 nights)175.10 h (~21.9 nights)
CPAP, heated tube, AC plugContinuous 8 h75 WNonePure sine AC20.89 h (~2.6 nights)41.78 h (~5.2 nights)
CPAP, no heat, AC plugContinuous 8 h15 WNonePure sine AC104.45 h208.90 h
Inogen One G5 POC (setting 3), DCDemand pulse25 WNoneDC or AC70.04 h140.08 h
5 L stationary oxygen concentratorContinuous300 W~450 WPure sine AC5.22 h10.44 h
Refrigerator (18 cu ft)~35% compressor duty60 W avg (180 W run)800–1,200 WPure sine AC26.11 h52.22 h
Lift chair / hospital bedIntermittent, 2-min cycles200 W in use (~6.7 Wh/cycle)~350 WPure sine AC~235 cycles~470 cycles
Wi-Fi router + fiber ONTContinuous 24/715 WNoneAC (DC if adapter available)104.45 h AC208.90 h AC
Calculated Loads are typical planning values; measure your own device. 0.90 usable × 0.85 AC or 0.95 DC. Capacities are as listed for the named models; confirm on official pages.

Runtime estimator

Uses the same published formula. Your browser does the arithmetic; nothing is sent anywhere.

87.55 hours

Assumes 90% usable capacity and constant load. Real runtime varies with temperature, battery age, inverter idle draw and device settings.

Which power stations are benchmarks for indoor medical backup?

Tier 1 favours lithium iron phosphate (LiFePO4). Compared with nickel-manganese-cobalt (NMC) cells in many older consumer units, LiFePO4 is more thermally stable and is commonly rated for thousands of cycles (makers often cite 3,000–4,000 cycles to 80% capacity). More stable is not the same as fire-proof.

BLUETTI AC200L

Figures as listed in the editorial brief
Base capacity ........ 2,048 Wh (expandable with B300-series packs)
Continuous output .... 2,400 W pure sine wave
UPS-style transfer ... ≤ 20 ms
DC ports ............. 48 V and 12 V outputs

EcoFlow DELTA Pro 3

Figures as listed in the editorial brief
Base capacity ........ 4,096 Wh (expandable with extra batteries)
Continuous output .... 4,000 W, 120 V / 240 V
UPS-style transfer ... ≤ 10 ms (switchover, not a true online UPS)
Noise ................ quiet at moderate load; fans run under heavy load

Pending verification These two models' figures have not yet been tied to an official document on this site. Verify them on the manufacturers' current pages before purchase.

Is UPS pass-through mode good enough for life-critical equipment?

Both benchmark units support pass-through charging, so equipment stays plugged in when the grid drops:

  1. Plug the power station into a wall outlet.
  2. Plug the CPAP, concentrator or router into the station.
  3. On grid power, the station passes power through and keeps its battery charged.
  4. When the grid drops, an internal relay switches the load to battery, typically within 10–20 ms per maker claims.

How do I recharge a battery during a week-long outage?

A battery is a finite tank. For 5–7 day outages, stored energy must be replenished without bringing combustion indoors.

Three recharge paths into a Tier 1 stationSolar PV200–400 W foldingVehicle 12 V100–200 W, car outdoorsInverter genoutdoors, short runStationindoors
Three recharge paths into a Tier 1 station

Portable folding solar arrays (200–400 W)

Set up on a south-facing deck, balcony or yard. A 400 W array might deliver roughly 1.2–1.6 kWh on a clear day, depending on season, angle and shading. Planning estimate Silent and fuel-free.

Vehicle 12 V/24 V auxiliary input

When cloud rules out solar, a 12 V car charging cable can feed the station's DC input at roughly 100–200 W. The vehicle must be outdoors in the open, never in an attached garage, even with the door up. About 3 hours of charging might restore roughly 450 Wh. Planning estimate

The hybrid gas-battery routine

Rather than running a generator all day, run a compact inverter generator outdoors, at least 20 ft from doors, windows and vents with exhaust pointed away, for a short daily window and charge the station at its maximum rated AC input, then shut the generator off. Use CO alarms indoors. CDC — Carbon monoxide poisoning prevention

Which accessories should I buy with a Tier 1 system?

  • Device maker's 12 V/24 V DC CPAP adapter, specific to your model (e.g., ResMed's DC converter for AirSense 11).
  • Solar extension cables (MC4 / XT60, 10 AWG) to limit voltage drop. Route through a window without pinching the cable or blocking egress.
  • Plug-in watt meter to measure real running and idle draw before an outage.
  • Battery-backed CO alarms if any combustion recharge method is part of your plan.

Which sources is this page based on?

Figures marked Planning estimate are illustrative ranges for budgeting and comparison. They are not measured test results, quotes, or verified benchmarks. Reserve has not performed hands-on testing of the equipment named here.

Frequently asked questions

How long will a 2,000 Wh battery run a CPAP machine?

Using the Reserve formula, a 2,048 Wh LiFePO4 station runs a 20 W CPAP on a DC adapter (humidifier and heated tube off) for about 87.5 hours, about 11 eight-hour nights. On AC with a heated humidifier at 75 W, runtime falls to about 20.9 hours, roughly 2.6 nights. Measure your own machine's draw; settings change it substantially.

Why use a DC adapter instead of the AC plug for a CPAP on a power station?

The AC route converts battery DC to 120 V AC and the CPAP power supply converts it back to DC, losing energy as heat and keeping the inverter running. An approved DC adapter from the CPAP maker avoids that double conversion. Reserve models AC at 85% efficiency and DC at 95%.

Are LiFePO4 power stations safe to use in a bedroom during an outage?

They produce no carbon monoxide in normal operation and LiFePO4 chemistry is more thermally stable than many other lithium chemistries, but no battery is fire-proof or 100% safe. Use the station indoors only where its listing and manual allow, keep clearances, avoid covering vents and follow charging temperature limits.

Will a power station's UPS mode keep my medical device running without interruption?

Not guaranteed. A 10–20 ms switchover is not a true online UPS, and some devices may reset or alarm. Ask the device maker and your clinician what backup is approved, test the setup before you need it, and keep an independent contingency such as a spare charged battery or a plan to relocate.